Technical data:
040100 Comfort 75
Circulation power 8,000 l/h
self-priming pump with pre-lter
maximum water temperature 35 °C
230 V / 550 W
Integrated timer switch
7 way valve with pressure gauge
Tank Ø 400 mm
Connector Ø 32/38 mm
Special adapter for INTEX pools
Ground plate
requires approx. 25 kg sand
recommended grain size 0.7 - 1.2 mm
for pools up to 40,000 l capacity
Socket for optional connection for UV system Speed UV built into lter covering
040200 Comfort 50
Circulation power 6,600 l/h
self-priming pump with pre-lter
maximum water temperature 35 °C
230 V / 450 W
Integrated timer switch
7 way valve with pressure gauge
Tank Ø 400 mm
Connector Ø 32/38 mm
Preparation for INTEX special adapter
Ground plate
requires approx. 15 kg sand
recommended grain size 0.7 - 1.2 mm
for pools up to 33,000 l capacity
Socket for optional connection for UV system Speed UV built into lter covering
Problem treatment
Malfunction Cause Solution
Pressure gau-
ge has reading
over 1 bar
Dirty lter bed Backwash the lter (position
4)
Pressure is
too low
Hair and lint strainer
basket is dirty; Pump
gets too little water
Clean the hair and lint strai-
ner; check the suction line
and the water level
Air in the
pump
Poor seal on the
intake side of the
pump.
Tighten hose clamps and
connecting ttings.
Leaking lter
Seal Defective Check the seal, replace if
needed
Pump does
not run
Not plugged in
Check the socket and power
cord
G.F.C.I/ or main cir-
cuit breaker tripped
Schalten Sie den FI-Schutz-
schalter wieder ein. Löst die-
ser sofort wieder aus, liegt
ein Defekt an der Pumpe
oder der Ansteuerung vor.
Pump motor defec-
tive
Replace the entire pump
Sand in Pool If the sand is newly
replaced, the under-
sized grains are still
present
Switch on the breaker (if it is
immediately tripped again,
there is a defect in pump or
controls)
Sand in Central Val-
ve (from backwash)
Purge into drainpipe for 30
seconds (position 6)
Separation wall in
lter is improperly
installed
Check the separation wall
for proper positioning
Filter bottom strainer
is damaged
Replace the lter bottom
strainer
Air in system Loosen, but do not remove,
the transparency cover on
the lter tank to allow any
trapped air to escape. Tigh-
ten the cover once all of the
air has escaped
Important Note
To winterize the system
Unplug the pump from the power source.
Close the shut off valves or block the ow of water at the pool inlet and return
ports.
Disconnect the ltration system from the pool, drain the tank and hoses.
Place the handle on the central valve in position ‘Winterize’ to relieve the tension
on the spring and internal valve components.
Changing the lter sand
The lter sand should be changed every 2-3 years, depending on how much the
lter system is operated.
Care instructions
Visible contaminants are removed through the ltration system. This is not true
for algae, bacteria and other microorganisms, which are also a constant threat to
clear, clean and healthy pool water. For their prevention or removal, special water
treatment is available, properly and permanently dosed, guarantee for swimmers
any kind of harassment and ensure proper hygienic bath water.
Cleaning
Use conventional cleaning products. Do not use solvent-based or abrasive cleaning
agents/tools, i.e. no hard sponges, brushes etc..
Storage
The product must be thoroughly dried after cleaning. After which, it is to be stored in
a dry location protected from frost.
Disposal
Disposing of packaging: The packaging material has been selected in view of
environmental concerns and disposability and is therefore recyclable. The paper
and cardboard can be recycled, as can the plastic coverings.
Disposing of the product: Applicable in the European Union and other European
states with systems in place for collecting and sorting recyclable materials. Dispose
of the product in accordance with any laws and regulations applicable at your place
of residence.
Warranty conditions
The respective country’s legal provisions for warranty conditions shall apply accor-
dingly. For Austria and Germany, these apply for 2 years after the date of invoice.
Declaration of conformity (CE)
The EU declaration of conformity can be requested via the address shown at the
end of this manual.
Symbol explanation
CE: Declaration of Conformity (see “Declaration of Conformity” chapter): This
symbol designates products which full all applicable community regulations of the
European Economic Area.
EN

Related product manuals