GB Installation Instructions

Safety Warnings

Disconnect mains power before any work on the unit and ensure wiring is dead.

Principle of Operation

Explains how the integrated infrared sensor detects heat from moving objects.

Installation and Wall Mounting Guidance

Guidance on selecting installation site and height for optimal sensor performance.

Connecting the Mains Supply Lead

Details on connecting the 3-phase mains lead (L, N, PE) correctly.

Technical Specifications

Lists key technical details like wattage, voltage, angle of coverage, and IP rating.

Product Functions and Adjustments

Switch-OFF Delay (Time Setting)

Adjustable time for light to stay on after motion stops, from 5 sec. to 15 min.

Manual Override Function

Allows manual control of the light, including a 4-hour override mode.

Soft Light Start Feature

Describes the gradual increase and decrease of light brightness upon activation.

Reach Setting and Adjustment

How to adjust the sensor's detection range using provided shrouds.

Operation and Maintenance Guidelines

Guidance on operating the sensor light and cleaning the detector lens.

Troubleshooting Common Issues

Sensor Light Without Power

Troubleshooting steps for when the sensor light has no power.

Sensor Light Fails to Switch ON

Steps to diagnose why the sensor light is not turning on.

Sensor Light Fails to Switch OFF

Steps to diagnose why the sensor light is not turning off.

Unwanted Sensor Light Activation

Troubleshooting for unwanted activation of the sensor light.

LED Permanently ON

Diagnosing the issue of the LED staying on continuously without manual override.

Functional Warranty and Repair Service

Functional Warranty Details

Explains the warranty terms, duration, and conditions for the STEINEL product.

Repair Service Information

Information on how to get the product repaired after the warranty period.