MAINTENANCE MANUAL
STEMME TSA-M
MAINTENANCE MANUAL
STEMME TSA-M
10-30-00
Page 201
RETURN TO SERVICE
1. After Storage with Duration of 5 - 30 Days
A. After storage with duration of between 5 and 30 days, the following procedures are necessary for
returning to service:
(1) Perform a complete preflight check
2. After Storage with a Duration from 30 up to 90 Days
A. After storage with duration from 30 to 90 days, the following procedures are necessary for
returning to service:
(1) Remove aircraft from blocks (Refer to Chapter 07 "Lifting and Shoring").
(2) Engine
(a) In accordance with the practiced preserving measures, return engine to service as
described in the ROTAX Operator's Manual for installed engine model.
(b) After removing spark plugs, rotate propeller several revolutions. Then reinstall spark
plugs.
(c) Check oil level and grade.
(3) Fuel system
(a) Check fuel filter and clean it if necessary
(b) Check fuel tanks and lines for water and sediment. Drain fuel into clear cup and check
for water and sediment. Drain until water or sediment is gone.
(4) Electrical System
(a) Check battery and install.
(b) Remove all covers, which have been installed against corrosion at separate connections
and restore connection.
(5) Airframe
(a) Remove any installed locks and all materials to cover openings.
(6) Perform a thorough preflight inspection.
Nov 18/11