18
Heated Hose & Wand (optional)
CAUTION: DO NOT turn on the wand heat unless the hose is filled with material. Damage to
equipment may result.
The application wand and hose may be equipped with an optional electrical heating element.
This heating element prevents the product from freezing in the hose and wand. The electric
wand thermostat should be set to the desired temperature 30-40 minutes before trying to
pump product through the hose and wand. This will allow time for the product to re-liquefy in
the hose.
NOTE: No flushing or clean-up is required with this system. Just shut the machine off as the
product in the hose can be remelted by activating the wand heat.
Engine Operations (optional)
1. Engine Starting
a. Check all fluid levels.
b. Check reduction drive oil level.
c. Open fuel valve at fuel tank.
d. Start engine. (see manual insert)
e. Set the engine speed to the desired level.
2. Turning OFF Engine
a. To stop engine, move throttle to the idle position.
b. Allow a two minute cool down period at idle.
c. Shut OFF engine.
d. Refer to the engine manufacturers operators manual for additional information.
Murphy Shut Down Switch (optional)
If the engine is equipped with a Murphy switch it must be held in while starting the engine.
Once the engine is started the release the switch. If the oil pressure or engine temperature
limits are exceeded, the Murphy switch will shut down the engine, protecting it from damage.