Spécifications Cobalt “PLUS”(non homologué) et homologué :
MODÈLE
SCM-200/
SCMV-200
*
SCM-320/
SCMV-320
*
SCM-600/
SCMV-600
*
SCM-740/
SCMV-740
*
Débit
NSF 55 Classe B
16mJ/cm
2
à un TUV de 70 %
*
16,7 lpm
(4,4 gpm)
(1,0 m
3
/hr)
26,1 lpm
(6,9 gpm)
(1,6 m
3
/hr)
42,2 lpm
(11,1 gpm)
(2,5 m
3
/hr)
59,8 lpm
(15,8 gpm)
(3,6 m
3
/hr)
Santé publique USA
16mJ/cm
2
à un TUV de 95 %
56,8 lpm
(15 gpm)
(3,4 m
3
/hr)
94,6 lpm
(25 gpm)
(5,7 m
3
/hr)
227,1 lpm
(60 gpm)
(13,6 m
3
/hr)
227,1 lpm
(60 gpm)
(13,6 m
3
/hr)
Standard VIQUA
30 MJ/cm
2
à un TUV de 95 %
30,3 lpm
(8 gpm)
(1,8 m
3
/hr)
49,2 lpm
(13 gpm)
(3,0 m
3
/hr)
121,1 lpm
(32 gpm)
(7,3 m
3
/hr)
151,4 lpm
(40 gpm)
(9,1 m
3
/hr)
NSF/EPA
40 MJ/cm
2
à un TUV de 95 %
22,7 lpm
(6 gpm)
(1,4 m
3
/hr)
37,8 lpm
(10 gpm)
(2,3 m
3
/hr)
90,8 lpm
(24 gpm)
(5,5 m
3
/hr)
113,6 lpm
(30 gpm)
(6,8 m
3
/hr)
Dimensions
Réacteur
45,2 x 8,9 cm
(17,8 po x 3,5 po)
57,9 x 8,9 cm
(22,8 po x 3,5 po)
78 x 8,9 cm
(30,7 po x 3,5 po)
100 x 6,4 cm
(39,7 po x 2,5 po)
Contrôleur 24,1 cm x 8,1 cm x 6,4 cm (9,4 po x 3,2 po x 2,5 po)
Dimension des orifices
d’entrée / de sortie
Combo
3/4 po FNPT/
1 po MNPT
Combo
3/4 po FNPT/
1 po MNPT
1 po MNPT
1,5 po MNPT
Poids à l’expédition 5,4 kg (12 lb) 6,8 kg (15 lb) 8,6 kg (19 lb) 10,9 kg (24 lb)
Électricité
Tension 100-240 V/ 50-60 Hz 100-240 V/ 50-60 Hz 100-240 V/ 50-60 Hz 100-240 V/ 50-60 Hz
Consommation 35 W 42 W 70 W 82 W
Puissance de la lampe 27 W 34 W 58 W 70 W
Pression maximale
de service
8,62 bar
(125 psi)
8,62 bar
(125 psi)
8,62 bar
(125 psi)
8,62 bar
(125 psi)
Température
ambiante de l’eau
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
2-40 ˚C
(36-104 ˚F)
Type de lampe Sterilume
MC
– HO (high output) à flux élevé
Affichage – mise
sous tension
Oui
Oui Oui Oui
Alarme sonore
de défaillance
Oui Oui Oui Oui
Avertisseur – remplacement
de la lampe
Oui
Oui Oui Oui
Affichage – durée
d’opération résiduelle de
la lampe
Oui
Oui Oui Oui
Durée totale de
fonctionnement
Oui
Oui Oui Oui
Moniteur UV 254 nm
Oui
Oui Oui Oui
Sortie d’électrovanne
(électrovanne non comprise)
Oui
Oui Oui Oui
Sortie 4-20 mA
Oui (en
option 260134)
Oui (en
option 260134)
Oui (en
option 260134)
Oui (en
option 260134)
Matériau de la chambre
Inox 304 Inox 304 Inox 304 Inox 304
Limiteur
de débit
Dimensions
1 po MNPT 1 po MNPT 1 po MNPT 1,5 po MNPT
Longueur
(2,75 po) - 7 cm (2,75 po) - 7 cm (2,75 po) - 7 cm (2,75 po) - 7 cm
18
Specifications Cobalt “PLUS” (non-certified) and Certified:
MODEL SCM-200/
SCMV-200
*
SCM-320/
SCMV-320
*
SCM-600/
SCMV-600
*
SCM-740/
SCMV-740
*
Flow Rate
NSF 55 Class B
16mJ/cm
2
@ 70% UVT
*
16.7 lpm
(4.4 gpm)
(1.0 m
3
/hr)
26.1 lpm
(6.9 gpm)
(1.6 m
3
/hr)
42.2 lpm
(11.1 gpm)
(2.5 m
3
/hr)
59.8 lpm
(15.8 gpm)
(3.6 m
3
/hr)
US Public Health
16mJ/cm
2
@ 95% UVT
56.8 lpm
(15 gpm)
(3.4 m
3
/hr)
94.6 lpm
(25 gpm)
(5.7 m
3
/hr)
227.1 lpm
(60 gpm)
(13.6 m
3
/hr)
227.1 lpm
(60 gpm)
(13.6 m
3
/hr)
VIQUA Standard
30 mJ/cm
2
@ 95% UVT
30.3 lpm
(8 gpm)
(1.8 m
3
/hr)
49.2 lpm
(13 gpm)
(3.0 m
3
/hr)
121.1 lpm
(32 gpm)
(7.3 m
3
/hr)
151.4 lpm
(40 gpm)
(9.1 m
3
/hr)
NSF/EPA
40mJ/cm
2
@ 95% UVT
22.7 lpm
(6 gpm)
(1.4 m
3
/hr)
37.8 lpm
(10 gpm)
(2.3 m
3
/hr)
90.8 lpm
(24 gpm)
(5.5 m
3
/hr)
113.6 lpm
(30 gpm)
(6.8 m
3
/hr)
Dimensions
Reactor
45.2 x 8.9 cm
(17.8“ x 3.5“)
57.9 x 8.9 cm
(22.8“ x 3.5“)
78 x 8.9 cm
(30.7“ x 3.5“)
100 x 6.4 cm
(39.7“ x 2.5“)
Controller
24.1 cm x 8.1 cm x 6.4 cm
(9.4“ x 3.2“ x 2.5“)
Inlet/Outlet Port Size
Combo
3/4“ FNPT/
1“ MNPT
Combo
3/4“ FNPT/
1“ MNPT
1“ MNPT
1.5“ MNPT
Shipping Weight 5.4 kg (12 lbs) 6.8 kg (15 lbs) 8.6 kg (19 lbs) 10.9 kg (24 lbs)
Electrical
Voltage
100-240V/
50-60Hz
100-240V/
50-60Hz
100-240V/
50-60Hz
100-240V/
50-60Hz
Power
Consumption
35 W 42 W 70 W 82 W
Lamp Watts 27 W 34 W 58 W 70 W
Maximum Operating
Pressure
8.62 bar
(125 psi)
8.62 bar
(125 psi)
8.62 bar
(125 psi)
8.62 bar
(125 psi)
Ambient Water
Temperature
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
2-40˚C
(36-104˚F)
Lamp Type Sterilume™-HO (high-output)
Visual “Power-On” Yes Yes Yes Yes
Audible Lamp Failure Yes Yes Yes Yes
Lamp Replacement
Reminder
Yes Yes Yes Yes
Visual Lamp Life
Remaining
Yes Yes Yes Yes
Total Running Time Yes Yes Yes Yes
254nm UV Monitor Yes Yes Yes Yes
Solenoid Output
(solenoid not incl.)
Yes Yes Yes Yes
4-20 mA Output
Yes (optional
260134)
Yes (optional
260134)
Yes (optional
260134)
Yes (optional
260134)
Chamber Material 304 SS 304 SS 304 SS 304 SS
Flow Restrictor
Size 1” MNPT 1” MNPT 1” MNPT 1.5” MNPT
Length (2.75”) 7 cm (2.75”) 7 cm (2.75”) 7 cm (2.75”) 7 cm
18