25
values remain constant for a particular part ID.
17 idtArE F ID Memory Tare configuration
Selects the information stored when ID memory is
used. Select:
F - No tare weight will be recalled with the stored
ID memory.
t - If the tare weight will be recalled along with
total quantity accumulation when the ID memory
is used. Stored tare weights can be used for
counting parts. Use this mode if tare values
remain constant for a particular part ID.
18 out nonE Data Output Mode
Selects the conditions required for serial data
output to occur. Select:
nonE - If serial data output is disabled.
Prnt - If serial output is to occur when the PRINT
key is pressed. The XC780 must be in the
weigh or count mode and the scale weight must
be stable.
Cont - If serial data output occurs continuously when
the XC780 is in weigh or count mode,
regardless of scale weight or stability.
StbL - If serial data output occurs continuously when
the XC780 is in weigh or count mode, ONLY when
the scale weight is stable.
Auto - If serial data output is to occur ONCE when
the scale net weight exceeds 0.04% of capacity
and the scale weight is stable(no motion).
The scale gross weight must return to near
zero before the next data output can occur.
Near zero is less than .04% of full scale capacity.
19 bPS 9600 RS-232C Baud Rate(Bits Per Second)
Selects the baud rate for serial RS-232C data
interface. The baud rate of the XC780 must match the
connected device. Higher baud rates yield faster
data transmission. Lower baud rates allow longer
cables and more secure data transmission. Select:
9600 - 9600 bits per second.
19200 - 19200 bits per second.
150 - 150 bits per second.
300 - 300 bits per second.
600 - 600 bits per second.
1200 - 1200 bits per second.
2400 - 2400 bits per second.
4800 - 4800 bits per second.