27
Enters program mode for Customized Ticket Format or
Special Programmable Output format. Select:
F - If not programming format of if standard data
output mode was selected.
t - If programming data output. The type of format
to be programmed is selected by the "FMt "
parameter. See the "Custom Printer Format" or
"Special Programmable Output" section in the
XC780 Technical manual for details on how to
program a format.
25 bEEPEr t Beeper Enable
Turns the beeper(Audio transducer) on and off. Any
modification will not take effect until parameters
are exited. Select:
t - Beeper sounds when a key is pushed.
F - Beeper does not sound when a key is pushed.
26 StAtn F Station Number
Allows a station number to be assigned to the XC780.
The station number can be output to a printer or host
computer and is required when using the XC780 in a
multi-drop communications network. Select:
F - If not entering or modifying the station number.
t - If entering or modifying the station number.
After selecting t(rue) proceed with the following
steps:
1) The XC780 will prompt with "Sttn XX" where XX
is the current station number.
2) Enter the desired number (0-99) on the numeric
keypad. If [0] is entered the station number will
not be output from the RS-232C port. If using the
XC780 in a multi-drop network, each XC780 on the
network must have a unique, non-zero station number.
3) Press the print key to save the new station
number in non-volatile memory.
27 SErno F Transaction Serial (Sequential) Number
Allows the transaction serial number to be entered
or modified. The serial number is used to identify
a particular scale transaction and can be output to
a printer or computer. After the scale data is
output, the serial number is automatically
incremented by one. Select:
F - If not entering or modifying the transaction
serial number.
t - If entering or modifying the transaction serial
number. After selecting t(rue) proceed with the
following steps:
1) The XC780 will prompt with "Sn XXXXX" where XXXXX