INSTALLATION
Preparation
38 | DEM www.stiebel-eltron.com
8.2 Accessories
Special aerator
Note
Fitting the special aerator supplied provides an optimum
water jet.
Non-pressurised taps
- WSN10 / WSN20 - sensor tap for washbasins
- MAW - wall mounted tap for oversink installation
- MAZ - twin lever washbasin tap
- MAE - mono lever washbasin tap
Pressure-tested tap
- WSH10 / WSH20 - sensor tap for washbasins
9. Preparation
f Flush the water line thoroughly.
Water installation
No safety valve is required.
Taps
f Use suitable taps (see chapter "Installation/ Appliance de-
scription/ Accessories").
10. Installation
10.1 Installation site
Install the appliance in a room free from the risk of frost and near
the draw-off tap.
Ensure that the lateral fixing screws for the cover are always ac-
cessible.
The appliance is suitable for undersink installation (water con-
nections at the top) and oversink installation (water connections
at the bottom).
DANGER Electrocution
The adjusting screw for setting the flow rate is live. Pro-
tection rating IP25 is only ensured if the appliance back
panel is fitted.
f Always fit the appliance back panel.