ENGLISH
www.stiebel-eltron.com DEM | 49
INSTALLATION
15.2 Wiring diagram
15.2.1 DEM 3
1/N/PE ~ 200-240 V
L N
p >
L N
ϑ
V >
D0000035308
1
2
3
1 Safety pressure limiter
2 Pressure differential switch
3 PCB with outlet temperature sensor
15.2.2 DEM 4 and DEM 6
1/N/PE ~ 200-240V
L N
p >
L N
ϑ
V >
85_02_05_0001
1
2
3
1 Safety pressure limiter
2 Pressure differential switch
3 PCB with outlet temperature sensor
!
Property damage
f In the case of a permanent power supply, connect
the power cable according to the designations on
the socket terminals.