42 | DEM www.stiebel-eltron.com
Appliance installation
Fit the appliance to the tap with the water connections.
10.3 Connecting the power supply
DANGER Electrocution
Carry out all electrical connection and installation work
in accordance with regulations.
DANGER Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3mm contact separation.
DANGER Electrocution
The appliances are delivered with a power cable (DEM3
with plug).
Connection to a permanent power supply is possible,
provided the fixed cable has a cross-section that is at
least equal to that of the standard power cable of the
appliance. A maximum cross-section of 3x6mm² may
be used.
If the appliance is installed over the sink, route the
power cable behind the appliance.
!
Material losses
When making the connection to a standard safety socket
(in the case of a power cable with plug), ensure that the
socket is freely accessible after the appliance has been
installed.
!
Material losses
Take note of the type plate. The specified voltage must
match the mains voltage.
Connect the power cable as shown in the wiring diagram
(see chapter “Specification/ Wiring diagram”).
11. Commissioning
11.1 Initial start-up
26�02�05�0087
Fill the appliance by running the tap several times until the
pipework and appliance are free of air.
Carry out a tightness check.