16.3 DHW output
The DHW output is subject to the mains voltage, the appliance’s
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate (see
chapter “Operation/ Troubleshooting”).
Connected load in kW 38 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V 400 V 415 V 5°C 10°C 15°C 20°C
10,1 4,4 5,2 6,3 8,0
11 4,8 5,6 6,8 8,7
12,2 5,3 6,2 7,6 9,7
13,5 5,8 6,9 8,4 10,7
14,5 6,3 7,4 9,0 11,5
16,2 7,0 8,3 10,1 12,9
18 7,8 9,2 11,2 14,3
19,4 8,4 9,9 12,0 15,4
16,2 7,0 8,3 10,1 12,9
19 8,2 9,7 11,8 15,1
21,7 9,4 11,1 13,5 17,2
18 7,8 9,2 11,2 14,3
21 9,1 10,7 13,0 16,7
24 10,4 12,2 14,9 19,0
19,4 8,4 9,9 12,0 15,4
22,6 9,8 11,5 14,0 17,9
25,8 11,2 13,2 16,0 20,5
24,4 10,6 12,4 15,2 19,4
27 11,7 13,8 16,8 21,4
Connected load in kW 50 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V 400 V 415 V 5°C 10°C 15°C 20°C
10,1 3,2 3,6 4,1 4,8
11 3,5 3,9 4,5 5,2
12,2 3,9 4,4 5,0 5,8
13,5 4,3 4,8 5,5 6,4
14,5 4,6 5,2 5,9 6,9
16,2 5,1 5,8 6,6 7,7
18 5,7 6,4 7,3 8,6
19,4 6,2 6,9 7,9 9,2
16,2 5,1 5,8 6,6 7,7
19 6,0 6,8 7,8 9,0
21,7 6,9 7,8 8,9 10,3
Connected load in kW 50 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V 400 V 415 V 5°C 10°C 15°C 20°C
18 5,7 6,4 7,3 8,6
21 6,7 7,5 8,6 10,0
24 7,6 8,6 9,8 11,4
19,4 6,2 6,9 7,9 9,2
22,6 7,2 8,1 9,2 10,8
25,8 8,2 9,2 10,5 12,3
24,4 7,7 8,7 10,0 11,6
27 8,6 9,6 11,0 12,9
16.4 Application areas/ conversion table
Specific electrical resistance and specific electrical conductivity
(see chapter “Installation/ Data table”).
Standard specifica-
tion at 15 °C
20°C
25°C
Resist-
ance
ρ ≥
Conductivity σ
Resist-
ance
ρ ≥
Conductivity σ
Resist-
ance
ρ ≥
Conductivity σ
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
900 111 1111 800 125 1250 735 136 1361
1000 100 1000 890 112 1124 815 123 1227
1100 91 909 970 103 1031 895 112 1117
1200 83 833 1070 93 935 985 102 1015
1300 77 769 1175 85 851 1072 93 933
16.5 Pressure drop
Taps/valves
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Shower head, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1MPa is recommended.
16.6 Details on energy consumption
The product data complies with EU regulations relating to the
Directive on the ecological design of energy related products (ErP).
DHB-E 11 SLi DHB-E 13 SLi DHB-E 18 SLi 25 A DHB-E 18/21/24 SLi DHB-E 27 SLi
232013 232014 232015 232016 232017
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile S S S S S
Energy efficiency class A A A A A
Annual power consumption kWh 472 472 477 477 481
Energy conversion efficiency % 39 39 39 39 39
Default temperature setting °C 60 60 60 60 60
Sound power level dB(A) 15 15 15 15 15
Special information on measuring efficiency None None None Data at Pmax. None