ENGLISH
www.stiebel-eltron.com DHE AU| 15
INSTALLATION
Service mode
11.1 Initial start-up
on
on
26�02�02�0554
Open and close all connected draw-off valves several times,
until all air has been purged from the pipework and the
appliance.
Carry out a tightness check.
Activate the safety switch (AE 3) by firmly pressing the reset
button (the appliance is delivered with the safety switch
deactivated).
Push the set value transducer cable plug onto the PCB.
Fit the appliance cover and secure it with the screw.
Switch the power supply ON.
Check the appliance function.
Remove the protective foil from the control fascia.
Appliance handover
Explain the appliance function to users and familiarise them
with how it works.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions.
11.2 Recommissioning
See chapter "Settings and displays / Following an interruption to
the water supply"
12. Service mode
D0000046159
Open the appliance cover and hook it on the side of the back
panel.
26�02�02�0556�
1
1 Service button for activating and deactivating service mode
Key to symbols
Press once START
Press once END
Change settings/ scanning
In service mode you are able to call up and/or change the set
temperature using the M key (60°C).