www.stiebel-eltron.com DHF-C | 29
GUARANTEE | ENVIRONMENT AND RECYCLING
GUARANTEE
ENVIRONMENT AND RECYCLING
15.3 DHW output
The DHW output is subject to the mains voltage, the appliance's
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate (see
chapter "Installation/ Troubleshooting").
Connected load in kW 38 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
220 V 230 V 400 V 5°C 10°C 15°C 20°C
8 3,5 4,1 5,0 6,3
12 5,2 6,1 7,5 9,5
6,6 2,9 3,4 4,1 5,2
8,8 3,8 4,5 5,5 7,0
13,2 5,7 6,7 8,2 10,5
6,6 2,9 3,4 4,1 5,2
7,5 3,2 3,8 4,7 6,0
9 3,9 4,6 5,6 7,1
10,5 4,5 5,4 6,5 8,3
13,2 5,7 6,7 8,2 10,5
15 6,5 7,7 9,3 11,9
18 7,8 9,2 11,2 14,3
21 9,1 10,7 13,0 16,7
24 10,4 12,2 14,9 19,0
Connected load in kW 50 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
220 V 230 V 400 V 5°C 10°C 15°C 20°C
8 2,5 2,9 3,3 3,8
12 3,8 4,3 4,9 5,7
6,6 2,1 2,4 2,7 3,1
8,8 2,8 3,1 3,6 4,2
13,2 4,2 4,7 5,4 6,3
6,6 2,1 2,4 2,7 3,1
7,5 2,4 2,7 3,1 3,6
9 2,9 3,2 3,7 4,3
10,5 3,3 3,8 4,3 5,0
13,2 4,2 4,7 5,4 6,3
15 4,8 5,4 6,1 7,1
18 5,7 6,4 7,3 8,6
21 6,7 7,5 8,6 10,0
24 7,6 8,6 9,8 11,4
15.4 Pressure drop
Taps/valves
Pressure drop at taps at flow rate of 10 l/min
Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Hand shower, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1MPa is recommended.