1. Operating instructions for the user and the qualied installer
Heating-up time
* Cold water intake 15 °C
Temperature setting 75 °C
What to do if...?
Type Heating-up time
EHS 15
0 h 43 min
EHS 30
1 h 04 min
EHS 50
1 h 46 min
EHS 80
2 h 50 min
EHS 100
3 h 33 min
EHS 150
5 h 20 min
Fault Cause Rectication
The water discharge volume
has been clearly reduced
despite the water valve
being opened fully
The desired temperature is
not being reached.
The device is no longer
heating up.
– Heating element is
scalded up
– Incorrect positioning
of the temperature
– Heating element is
scalded up
– Device has incorrect
dimensions for its use
–Powersupply
disconnected
– Limiter has operated
– Heating element
defective
– Arrange for the
device to be descaled
by a qualied installer
(see also “Maintenance”).
– Regulator must be set
on correct position
– Device must be
descaled
– Change appliance to
bigger one
– Check the electricity
leads (fuses).
– Arrange to change the
complete safety thermal
cut-out
– Change the heating
ange
– Reset the ELCB