STIEBEL ELTRON
6
2. Installation instructions for the qualied installer
Installation instructions
for the installer
Regulations and provisions
– General national regulations
– Regulations of the local water
authority
– Regulations of the local electricity
authority
– Rating plate
Installation location
– Install horizontal as in Fig. C
– In an area free of the risk of freezing
– Install in the vicinity of the water tap
Equipment installation
– Install the device Fig. E
When installing the device, select
securing materials to suit the
stability of the wall
Water connection Fig. F,G
Unvented (pressurized) for the supply
of several draw-off points.
A safety valve must be fitted
at the cold water inlet of the
unit, by a skilled installer.
Notewithregardtocopper
pipes:Noconnectionsmade
of copper may be installed directly on
the device. We recommend that red
brass or plastic transition fittings be
used as connection isolators for the
pipe connections.
Parts Fig H
Steel tank enamelled with heating
flange with incoloy heating element
and protection anode. For test mark:
see rating plate protection mode
IPX4.
- Cold water connection nozzle (blue)
- Hot water connection nozzle (red)
Technical data
Type EHS 15 30 50 80 100 150
Content
Weight, empty
Powerrating
Voltage
Permissibleoperatingpressure
l
kg.
W
V
bar
15
9.7
1500
220
7
30
13.2
2000
220
7
50
17.5
2000
220
7
80
23.7
2000
220
7
100
27.8
2000
220
7
150
37.6
2000
220
7
Fig. B
Type EHS 15 30 50 80 100 150
A
B
C
D
E
mm.
mm.
mm.
mm.
mm.
310
562
330
164
116
370
649
385
204
177
410
749
425
204
334
480
826
495
204
297
480
974
495
204
447
480
1294
495
204
767
English