22 | HSTP www.stiebel-eltron.COM
Installation
Specication
15.5 Replacing the heating elements
26�02�09�0069�
5
6
4
23
1
1 Insulation plate
2 Pressure plate
3 Soldered flange
4 Insulating plate
5 Corrosion resistor 390 Ω
6 Gasket
Ensure the heating elements are electrically isolated when
installing them in the flange plate.
The corrosion resistor acts to balance the potential and prevents
power leakage corrosion on the heating elements.
Never damage or remove the corrosion resistor during
maintenance.
After replacing the corrosion resistor, reassemble the flanged
immersion heater correctly.
16. Specification
16.1 Dimensions and connections
HSTP 200
1570
340
75
1035
690
550
430
45°
45°
c06
c10
i01
i18
a43
h40
c01
b02
b03
D0000018162
HSTP 200
a43 Appliance Pitch circle diameter of feet mm 430
a45 Feet fixing hole Diameter mm 19
b02 Entry electrical cables I Fitting PG 16
b03 Entry electrical cables II Fitting PG 13.5
c01 Cold waterInlet Male thread G 1 A
c06 DHW outlet Male thread G 1 A
c10 DHW circulation Male thread G 1/2 A
h40 Thermometer DHW Male thread G 1/2 A
i01 Flange
Diameter mm 210
Pitch circle diameter mm 180
Immersion depth mm 400
Screws M 12
Torque Nm 55
i18 Protective anode

Table of Contents