26 | HSTP www.stiebel-eltron.COM
Installation
Specication
16.3 Heat-up diagram
The heat-up time depends on the cylinder capacity, cold water
temperature and heating output.
Diagram with 10°C cold water temperature and temperature set-
ting "e":
2
4
6
8
84�02�02�0022
X Nominal capacity in l
Y Heat-up time in h
1 2 kW
2 3 kW
3 4 kW
4 6 kW
16.4 Fault conditions
In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
can occur.
16.5 Details on energy consumption
Product data complies with EU regulations relating to the Directive
on the ecodesign of energy related products (ErP).
HSTP 200 HSTP 300 HSTP 400
071264 071267 071270
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile XL XL XL
Energy efficiency class C C C
Energy conversion efficiency % 39 39 38
Annual power consumption kWh 4325 4333 4357
Default temperature setting °C 60 60 60
Sound power level dB(A) 15 15 15
Option for exclusive operation during off-peak periods - - -
Smart function - - -
Daily power consumption kWh 19.884 19.928 20.070
Cylinder capacity l 200 300 400
Mixed water volume at 40 °C l 392 582 768