EasyManua.ls Logo

STIEBEL ELTRON LWZ 8 CS Premium - Page 22

STIEBEL ELTRON LWZ 8 CS Premium
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...


22 
      
 FAN STAGE VENT. AIR 1 m³/h 10 300 140
 FAN STAGE VENT. AIR 2 m³/h 80 300 170
 FAN STAGE VENT. AIR 3 m³/h 80 300 220
 FAN STG. EXTRACT AIR 1 m³/h 10 300 140
 FAN STG. EXTRACT AIR 2 m³/h 80 300 170
 FAN STG. EXTRACT AIR 3 m³/h 80 300 220
 PASSIVE COOLING
 PASSIVE COOLING OFF| EXTRACT AIR| SUPPLY AIR| BYPASS|
SUMMER CASSETTE
OFF
 PASS. COOL EXP. AIR OFF| ON OFF
 AIR STOP SUMMER DHW OFF| ON OFF
 HUMIDITY PROTECTION
 HUMIDITY PROTECTION OFF| ON OFF
 HUM. THRESHOLD VALUE % 30 70 55
 HUMIDITY HYSTERESIS % 2 10 5
 HUM. MASKING TIME min 1 10 5
 SET HUMIDITY MIN % 30 60 50
 OUTPUT REDUCTION % 0 50 0
 SET HUMIDITY MAX % 60 90 60
 OUTPUT INCREASE % 0 100 0
 STOVE / FIREPLACE OFF| N/O CONTACT OFF| N/C CONTACT OFF|
N/O MONITORING| N/C MONITORING
OFF
 AIR/AIR HE
 MAX DEFROST DUR. min 60 250 60
 DEFR START THRESHOLD 0 50 20
 FILTER SPEED 0 100 20
 FILTER CHANGE VOLUME 1000 m³ 180 650
 SERVICE
 RUNTIME FILTER d 0 1024 0
 RESET FILTER OFF| ON OFF
COOLING
 ROOM TEMPERATURES HC1
 ROOM TEMPERATURE DAY HC1 °C 10 30 25
 ROOM TEMP. NIGHT HC1 °C 10 30 25
 ROOM TEMP. STANDBY HC1 °C 10 30 30
 ROOM TEMPERATURE HC1 °C
 ROOM TEMPERATURES HC2
 ROOM TEMPERATURE DAY HC2 °C 10 30 25
 ROOM TEMP. NIGHT HC2 °C 10 30 25
 ROOM TEMP. STANDBY HC2 °C 10 30 30
 ROOM TEMPERATURE HC2 °C
 COOLING MODE HC1
 COOLING MODE HC1 OFF
 COOLING SYSTEM HC1 AREA COOLING | FAN COOLING AREA COOLING
 HC TEMP. COOLING HC1 °C 10 25 18
 HYST. ROOM TEMP. HC1 K 0.5 3 0.5
 COOLING MODE HC2
 COOLING MODE HC2 OFF| ON OFF ON OFF
 COOLING SYSTEM HC2 AREA COOLING | FAN COOLING AREA COOLING
 HC TEMP. COOLING HC2 °C 10 25 18
 HYST. ROOM TEMP. HC2 K 0.5 3 0.5
 STANDARD SETTING
 COOLING CAPACITY % 30 50 30
 HYST. FLOW TEMP. K 0.5 5 1.5
SOLAR THERMAL
 SOLAR ACTIVATION OFF| ON OFF ON OFF
 TEMP. DIFFERENTIAL K 2 15 8
 DHW COMPRESSOR DELAY min 0 500 60
 DHW SOLAR TEMP. °C 10 75 60
 SOLAR HYSTERESIS K 0.6 10 5
 COLLECTOR TEMP LIMIT °C 50 80 70
 COLL. PROTECT TEMP °C 100 150 120
 COLL. CUT-OFF TEMP °C 130 200 180
 COLLECTOR PROTECTION OFF| ON OFF
 PRIORITY SOLAR SOLAR THERMAL | COOLING | COOLING TIME SOLAR THERMAL