22
FAN STAGE VENT. AIR 1 m³/h 10 300 140
FAN STAGE VENT. AIR 2 m³/h 80 300 170
FAN STAGE VENT. AIR 3 m³/h 80 300 220
FAN STG. EXTRACT AIR 1 m³/h 10 300 140
FAN STG. EXTRACT AIR 2 m³/h 80 300 170
FAN STG. EXTRACT AIR 3 m³/h 80 300 220
PASSIVE COOLING
PASSIVE COOLING OFF| EXTRACT AIR| SUPPLY AIR| BYPASS|
SUMMER CASSETTE
OFF
PASS. COOL EXP. AIR OFF| ON OFF
AIR STOP SUMMER DHW OFF| ON OFF
HUMIDITY PROTECTION
HUMIDITY PROTECTION OFF| ON OFF
HUM. THRESHOLD VALUE % 30 70 55
HUMIDITY HYSTERESIS % 2 10 5
HUM. MASKING TIME min 1 10 5
SET HUMIDITY MIN % 30 60 50
OUTPUT REDUCTION % 0 50 0
SET HUMIDITY MAX % 60 90 60
OUTPUT INCREASE % 0 100 0
STOVE / FIREPLACE OFF| N/O CONTACT OFF| N/C CONTACT OFF|
N/O MONITORING| N/C MONITORING
OFF
AIR/AIR HE
MAX DEFROST DUR. min 60 250 60
DEFR START THRESHOLD 0 50 20
FILTER SPEED 0 100 20
FILTER CHANGE VOLUME 1000 m³ 180 650
SERVICE
RUNTIME FILTER d 0 1024 0
RESET FILTER OFF| ON OFF
COOLING
ROOM TEMPERATURES HC1
ROOM TEMPERATURE DAY HC1 °C 10 30 25
ROOM TEMP. NIGHT HC1 °C 10 30 25
ROOM TEMP. STANDBY HC1 °C 10 30 30
ROOM TEMPERATURE HC1 °C
ROOM TEMPERATURES HC2
ROOM TEMPERATURE DAY HC2 °C 10 30 25
ROOM TEMP. NIGHT HC2 °C 10 30 25
ROOM TEMP. STANDBY HC2 °C 10 30 30
ROOM TEMPERATURE HC2 °C
COOLING MODE HC1
COOLING MODE HC1 OFF
COOLING SYSTEM HC1 AREA COOLING | FAN COOLING AREA COOLING
HC TEMP. COOLING HC1 °C 10 25 18
HYST. ROOM TEMP. HC1 K 0.5 3 0.5
COOLING MODE HC2
COOLING MODE HC2 OFF| ON OFF ON OFF
COOLING SYSTEM HC2 AREA COOLING | FAN COOLING AREA COOLING
HC TEMP. COOLING HC2 °C 10 25 18
HYST. ROOM TEMP. HC2 K 0.5 3 0.5
STANDARD SETTING
COOLING CAPACITY % 30 50 30
HYST. FLOW TEMP. K 0.5 5 1.5
SOLAR THERMAL
SOLAR ACTIVATION OFF| ON OFF ON OFF
TEMP. DIFFERENTIAL K 2 15 8
DHW COMPRESSOR DELAY min 0 500 60
DHW SOLAR TEMP. °C 10 75 60
SOLAR HYSTERESIS K 0.6 10 5
COLLECTOR TEMP LIMIT °C 50 80 70
COLL. PROTECT TEMP °C 100 150 120
COLL. CUT-OFF TEMP °C 130 200 180
COLLECTOR PROTECTION OFF| ON OFF
PRIORITY SOLAR SOLAR THERMAL | COOLING | COOLING TIME SOLAR THERMAL