INSTALLATION

ENGLISH
www.stiebel-eltron.com PEO 18/21/24 | PEO 27 | 15
15.2 Wiring diagram
3/PE ~ 380-415 V
85�02�02�0005
1 Heating
2 High limit safety cut-out
3 Safety pressure limiter
Priority control with LR 1-A
85�02�02�0003�
2
1
1 Control cable to the contactor of the 2nd appliance (e.g. elec-
tric storage heater).
2 Control contact drops out when switching the instantaneous
water heater on.
15.3 DHW output
The DHW output is subject to the mains voltage, the appliance's
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate (see
chapter "Troubleshooting").
Connected load in kW 38 °C DHW output in l/min.
Rated voltage Cold water inlet temperature
380 V      
16.2 7.0 8.3 10.1 12.9
18.0 7.8 9.2 11.2 14.3
19.0 8.2 9.7 11.8 15.1
19.4 8.4 9.9 12.0 15.4
21.0 9.1 10.7 13.0 16.7
21.7 9.4 11.1 13.5 17.2
22.6 9.8 11.5 14.0 17.9
24.0 10.4 12.2 14.9 19.0
24.4 10.6 12.4 15.2 19.4
25.8 11.2 13.2 16.0 20.5
27.0 11.7 13.8 16.8 21.4
Connected load in kW 
Rated voltage Cold water inlet temperature
380 V      
16.2 5.1 5.8 6.6 7.7
18.0 5.7 6.4 7.3 8.6
19.0 6.0 6.8 7.8 9.0
19.4 6.2 6.9 7.9 9.2
21.0 6.7 7.5 8.6 10.0
21.7 6.9 7.8 8.9 10.3
22.6 7.2 8.1 9.2 10.8
24.0 7.6 8.6 9.8 11.4
24.4 7.7 8.7 10.0 11.6
25.8 8.2 9.2 10.5 12.3
27.0 8.6 9.6 11.0 12.9
15.4 Application areas/ Conversion table
Specific electrical resistivity and specific electrical conductivity
(see chapter "Data table").
Standard specifica-



Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
900 111 1111 800 125 1250 735 136 1361
1000 100 1000 890 112 1124 815 123 1227
1200 83 833 1070 93 935 985 102 1015
1300 77 769 1175 85 851 1072 93 933
15.5 Pressure drop
Taps
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Hand shower, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1MPa is recommended.
15.6 Fault conditions
In the event of a fault, loads up to a maximum of 95°C at a pres-
sure of 1.2MPa can occur temporarily in the installation.
15.7 Test symbols
See type plate on the appliance.