www.stiebel-eltron.com PEY 18/21/24 | 11
ENGLISH
INSTALLATION
Commissioning
10.2.7 Temperature limit
CAUTION Burns
When operating with preheated water, the set tempera-
ture limit may be ineffective.
In such cases, limit the temperature with an up-
stream central thermostatic valve.
You can adjust the temperature limit inside the appliance cover.
2
1
6 0 °
C
4
3
°
C
D0000046203
1 Max. 43°C
2 Max. 60°C
Connect the cable to position 1 (43°C).
The temperature can be set to between 30°C and 43°C.
10.3 Completing the installation
Open the shut-off valve in the twin connector or the cold
water inlet line.
11. Commissioning
WARNING Electrocution
Commissioning must only be carried out by a qualified
contractor in accordance with safety regulations.
11.1 Initial start-up
L
L
3
L
3
4
L
2
1
L
1
2
MV
NT C
T- soll
18
2
1
24
k W
D0000041613
Open and close all connected draw-off valves several times,
until all air has been purged from the pipework and the
appliance.
Carry out a tightness check.
Activate the safety pressure limiter by firmly pressing the reset
button (the appliance is delivered with the safety pressure
limiter deactivated).
Plug the temperature selector cable plug into the PCB.
Fit the appliance cover, ensuring it clicks into place. Check that
the appliance cover is seated correctly.
Switch the mains power ON.
Check the function of the appliance.