5. SHUTTING THE EQUIPMENT DOWN
14
Set switch 1 to OFF and remove the electrical supply at the isolating switch of the dedicated
heat pump circuit.
For reasons of good hygiene, drain the cylinder if it is taken out of use for longer periods
Draining the WWK 300
Turn off the WWK 300 as advised above.
Close all hot water taps
Operate the PTR valve release lever ( do not let the lever snap back as you will damage the
valve seat ) . This relieves the pressure in the WWK 300.
Undo the union at the cold water inlet and attach a hose. The other end of the hose goes to a
drain
Operate the relief valve again. This will let air into the unit and allow the water to drain through
the hose.