Malfunction: Pruning shears suddenly stop operating
Check component Cause Remedy
Testing the Battery
Insufficient state of charge
(1 LED on battery flashes green)
Charging the Battery
Battery too hot / too cold
(1 LED on battery glows red)
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Malfunction
(4 LEDs on battery flash red)
Remove the battery and refit it
Moisture in power tool's electronics or
battery
Allow power tool electronics or battery to
dry
Check all plugs No electrical contact Check connections – see Malfunction:
Cordless pruning shears do not run after
switch-on
Testing Connecting Cord
Move cordless pruning shears in all directions
and operate the trigger at the same time to
test function
Loose contact in connecting cord Have connecting cord checked by your
servicing dealer.
1)
1)
STIHL recommends an authorized STIHL servicing dealer.
Other malfunctions:
Malfunction: Cause Remedy
Rough cut
Cutting blade dull Sharpening the cutting blade
Too much play between cutting and anvil
blades
Adjust play between cutting and anvil
blades
Cutting blade worn Replacing the Cutting Blade
Battery jams when being fitted in battery
bag/charger
Guides / contacts dirty Use a blunt tool to carefully clean the
guides / contacts.
Battery is not being charged even though
LED on charger glows green
Battery too hot / too cold
(1 LED on battery glows red)
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Operate charger only in closed, dry
rooms at ambient temperatures of 5°C to
40°C (40°F to 104°F)