EasyManua.ls Logo

Stihl FSA 65 - Page 31

Stihl FSA 65
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FSA 65, FSA 85
English
29
Running time is too short
Battery is not fully charged Charge the battery
Using unsuitable nylon line Replace nylon line
Life of battery has been reached or
exceeded
Check battery
1)
and replace
Battery jams when being inserted in power
tool / charger
Guides / contacts dirty Carefully clean the guides / contacts
Battery is not being charged even though the
light emitting diode on the charger glows
green
Battery too hot / too cold
(1 light emitting diode on battery glows
red)
Allow battery to cool down / Warm up
battery slowly at a temperature of 60°F
to 70°F (15°C–20°C).
Operate the charger only in enclosed
and dry rooms at ambient temperatures
between 40°F (5°C) and 105°F (5°C–
40°C).
Light emitting diode on charger flashes red
No electrical contact between charger
and battery
Remove the battery and refit it again
Fault in battery
(4 light emitting diodes on battery flash
red for about 5 seconds)
Take the battery out of the power tool
and refit it. Switch on the power tool – if
the light emitting diodes still flash, the
battery is faulty and must be replaced.
Fault in charger Have charger checked by servicing
dealer
1)
1)
STIHL recommends a STIHL servicing dealer.
Always remove the battery before carrying out any work on the power tool.
Condition Cause Remedy