42
English
MS 210, MS 210 C, MS 230, MS 230 C, MS 250, MS 250 C
To shut down the engine:
: Move Master Control lever to $
At very low outside temperatures:
Allow the engine to warm up
As soon as the engine runs:
: Blip the throttle trigger to disengage
it from the starting throttle position.
The Master Control lever will move
to the operating position – engine
settles down to idling speed.
: Disengage the chain brake:
Pull hand guard back toward front
handle as shown in illustration.
: Open throttle partly – warm up
engine for short period.
If the engine doesn’t start:
If you did not move the Master Control
lever to warm start position n quickly
enough after the engine began to fire,
the combustion chamber is flooded.
: Press down the interlock lever and
move the Master Control lever to l
(cold start).
: Turn the twist lock 90° to the left.
: Lift off the carburetor box cover
vertically.
: Place fingers behind the air filter (3),
press thumbs against the housing
and swing filter in direction of rear
handle.
: Take out the shutter (4).
: Pull off the spark plug boot.
: Unscrew and dry off the spark plug.
: Set the Master Control lever to stop
position $.
: Crank the engine several times with
the starter to clear the combustion
chamber.
: Refit the spark plug. Connect the
spark plug boot and reassemble all
other parts.
: Set Master Control lever to n
– even if engine is cold.
: Now start the engine.
208BA005 KN
4
3
135BA001 KN