Metering Knob
N Rotate the metering knob (1) for 
infinitely variable discharge rate
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must 
be lined up with the lug (2) under the 
knob.
Discharge Rate
The discharge rate (l/min) depends on 
the metering knob setting and the spray 
tube angle.
Discharge rate (l/min) without pressure 
pump
Discharge rate (l/min) without pressure 
pump, with ULV nozzle 
Discharge rate (l/min) with pressure 
pump (special accessory)
Discharge rate (l/min) with pressure 
pump (special accessory) and ULV 
nozzle 
Checking Flow Rate
N Place the unit on the ground.
N Fill the container with water up to 
10 liter mark.
Machines without pressure pump
N Set the "standard" metering knob to 
6.
N Start the machine.
N Hold the spray tube horizontally, run 
the engine at full throttle, spray the 
contents of the container down to 
the 5 liter mark and note the time 
taken.
The time required to spray 5 liters fluid 
should be between 110 and 
150 seconds.
Machines with pressure pump (special 
accessory)
N Fit metering knob 2.0 in the nozzle.
N Start the machine.
N Hold the spray tube horizontally, run 
the engine at full throttle, spray the 
contents of the container down to 
the 5 liter mark and note the time 
taken.
The time required to spray 5 liters fluid 
should be between 100 and 
130 seconds.
Spray tube angle
Knob setting - 30° 0° + 30°
1 0.240.170.11
2 0.820.660.46
3 1.421.130.84
4 2.2 1.66 1.1
5 2.692.131.46
6 2.912.251.52
Spray tube angle
Knob setting - 30° 0° + 30°
0.5 0.050.040.03
0.65 0.08 0.07 0.05
0.8 0.120.090.08
Spray tube angle
Knob setting - 30° 0° + 30°
1.0 0.64
1.6 1.7
2.0 2.59
Spray tube angle
Knob setting - 30° 0° + 30°
0.5 0.15
0.65 0.2
0.8 0.37