EasyManua.ls Logo

Stihl SR 200 - Page 23

Stihl SR 200
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SR 200
English
21
Metering Knob
N Rotate the metering knob (1) for
infinitely variable discharge rate
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (2) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Checking Flow Rate
N Place the unit on the ground.
N Fill the container with water up to
10 liter mark.
Machines without pressure pump
N Set the "standard" metering knob to
6.
N Start the machine.
N Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 110 and
150 seconds.
Machines with pressure pump (special
accessory)
N Fit metering knob 2.0 in the nozzle.
N Start the machine.
N Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 100 and
130 seconds.
2
1
2431BA022 KN
0811BA019 KN
Spray tube angle
Knob setting - 30° + 30°
1 0.240.170.11
2 0.820.660.46
3 1.421.130.84
4 2.2 1.66 1.1
5 2.692.131.46
6 2.912.251.52
Spray tube angle
Knob setting - 30° + 30°
0.5 0.050.040.03
0.65 0.08 0.07 0.05
0.8 0.120.090.08
Spray tube angle
Knob setting - 30° + 30°
1.0 0.64
1.6 1.7
2.0 2.59
Spray tube angle
Knob setting - 30° + 30°
0.5 0.15
0.65 0.2
0.8 0.37

Related product manuals