In case of deviations:
N Check the container, hose system,
metering knob and optional
pressure pump for contamination
and clean if necessary.
N Check blower air intake and clean if
necessary.
N Check engine setting and correct if
necessary.
If there is no improvement, contact your
dealer for assistance.
N Turn the cap counterclockwise until
it can be removed from the
container opening.
N The gasket (1) in the cap must be in
good condition and clean.
N Stand the machine on a level
surface.
N Close valve lever (1) for solution
feed.
N Pour thoroughly mixed spray
solution into the container through
the strainer.
Do not exceed maximum fluid level of
10 liters (2.6 US.gals).
N Fit the cap and turn it clockwise with
both hands – tighten it as firmly as
possible.
Filling the Container