4
Maintenance
Turn the unit o and remove key. Disconnect the negave
baery cable and remove spark plug before performing any
maintenance.
Hydraulic System
• Hydraulic uid level should be checked daily.
Hydraulic Fluid Level Check Procedures:
1. Place unit on level ground. Locate the site glass on the hy-
draulic tank. (See gure 1)
2. Oil level should be half way up the glass. If not, please refer
to the hydraulic uid change procedure for adding addion-
al oil to the system.
• We recommend you change the hydraulic uid and lter
aer the rst 50 hours of use and then whichever comes
rst at least once/year or every 200-250 hours of use.
Figure 1 Figure 2