Specifications
Electrical
Contact Bounce 5 ms (max)
Contact Resistance 100 ohms (max)
Insulation Resistance 50 Mohms (min)
Breakdown Voltage 500 V AC (max 60 secs.)
Rating 5V DC 50mA (max)
Dimensions (mm)
Packed
W x H x D W x H x D Weight (kg) Weight (kg)
2210 289.5 118.5 35.8 410 195 75 1.05 w/poly keys 1.71 w/metal keys
2210 T/B 360 118.5 50 410 195 75 1.8 w/poly keys 1.95 w/metal keys
2212 T/B 384.5 142.5 50 410 195 75 2.1 w/poly keys 2.5 w/metal keys
2220 289.5 137.5 35.8 410 195 75 1.7 w/poly keys -
2230 346.5 137.5 35.8 410 195 75 1.8 w/poly keys -
Mechanical
Operational Life 4 million cycles (min) per key
Keytop Travel 1.5mm nominal
Actuation Force 100 grams nominal
Key Pitch 19mm
Performance/Regulatory
Operational Temp -20°C to +60°C
Impact Rating 5 J
Vibration/Shock ETSI 300 019 5M3
Water / Dust sealed IP65 (when fixed to suitable panel)
Certification CE / FCC / UL
EMC Emissions EN55032 : 2010 Class B Limit
EMC Immunity to ESD EN55024 : 2010 (15kV Air)
EMC Immunity to Radiated Fields EN55024 : 2010