V 11/17
53
Step five: connect the indoor unit pipe
1. Position the pipe joint in the
corresponding bellmouth.
2.
Pre-tighten the union nut by hand.
3.
Adjust the torque according to the
following table. Position the open-end
spanner on the pipe joint and position
the torque wrench on the union nut.
Tighten the nut with the wrench.
giunto pipe
tubo joint
dado union
raccordo nut
chiaveaforchetta open‐endspanner
Chiavedinamometrica wrench
Tubointerno innerpipe
dadoraccordo unionnut
tubo pipe
Hex nut diameter Tightening torque (Nm)
6.35
15 – 20
9.52
30 – 40
12.7
45 – 55
15.88
60 – 65
Tubo isolante insulatingtube
Wrap the indoor pipe and the joint of the
connecting pipe with an insulating tube. Then
wrap with tape.
Step six: install the condensate drain pipe
1. Connect the drain pipe to the outlet pipe
of the indoor unit.
2. Bind the joint
with tape.
Tubo isolante insulatingtube
tubodiuscita outletpipe
tubodiscarico drainpipe
nastro tape
N.B.:
• Add an insulating tube to the indoor drain pipe to
prevent condensation.
• The plastic wall plugs are not supplied.
dado raccordogiunto tubo
tubo
chiave
dinamometrica
chiave
a forchetta
tubo interno
tubo
dado raccordo
tubo isolante
tubo di scarico
nastro
tubo d'uscita
tubo di
uscita
tubo di scarico
tubo di scarico
tubo isolante