TECHNICAL DATA
6 WARNINGThis cooker must be earthed
Burner / Element Nat Gas / LPG
(kW) Injector (Nat
gas)
Injector
(LPG)
Butane g/h Propane g/h
Hob - small 1.00 77 50 73 72
Hob - medium (x2) 2.00 104 70 145 143
Hob - large 3.00 129 87 218 215
Hob - wok 4.00 152 100 291 286
Total heat input (5 burners) 12 N/A N/A N /A N /A
ELECTRICAL SUPPLY / LOAD
Electrical supply Oven Load (kW)
240 V
Digital oven 2.7 / 3.2
Fanned 1.7 / 2.1
Dual variable grill 1.7 / 2.1
Conventional top 1.2 / 1.4
Oven Lamps
Lamps (right hand oven) 25 W each
Lamp (left hand oven) 40 W each
Electrical supply Max. load (kW)
230/400V 3N ~ 50Hz 7.55 - 8.98