STRASBAUGH, INC.
August 11, 1995 6DS-SP Ver 4.15 Page 8
Backup Utility Batch File:
A backup utility batch file called "SBACKUP.BAT" ("Strasbaugh backup") is now
available so that certain files unique to a particular machine can be easily saved on a
diskette.
This can be used as an alternative to DOS backup utilities (which differ depending on
which version of DOS is on the machine.)
Procedure to backup files:
1) Turn the machine off and remove the polish section left-hand service door.
2) Pull on the service door interlock to defeat it.
3) Turn the machine back on and wait until the software restarts.
4) Quit the software by typing "Alt-Q". (Hold down the "Alt" and "Q" keys
together.) The prompt should now show "C:\QB45>".
5) Insert a diskette into the drive in the computer located behind the left-hand polish
section service door.
6) Type SBACKUP <Enter>.
The following files will automatically be copied to the diskette:
CALVARS.DAT (machine calibration values from Calibration menu)
LIFE.DAT (carrier and pad life wafer and time counters)
PASSWORD.DAT (stored passwords from Password menu)
ERRORS.DAT (errors logged and shown in Error Log menu )
SETUP.DAT (setup from Setup Menu)
RECIPE.DAT (current recipe data shown in recipe menus)
REC_NAME.DAT (name of currently used recipe)
INIT1.DAN (servo initialization for axes 1-8)
INIT2.DAN (servo initialization for axes 9-15)
*.REC (Stored recipes)
ALRMMASK.DAT (SECS option only - alarm message enable/disable)
7) Remove the diskette and appropriately label it.
8) Turn the machine off and replace the left-hand polish door.
9) Turn the machine on to restart the software.