Operations Model 6DS-SP Planarizer
4 - 18 Version 4.0 - February 1998
If the Left/Right choice is used, left and right parameter values can be
entered separately.
If the Matched choice is used, a value entered into either the left or right
parameter will also be entered into the other. Also, a small bracket line to
the left of the parameters will appear on both the Auto Polish Menu and the
Polish Parameters Menu to indicate that new entries will be linked.
Note: Changing from Left/Right to Matched will not change any
previously entered values.
"ON THE FLY" CHANGES:
As noted at the beginning of this chapter, a number of recipe parameter
changes can be made while the machine is operating.
For example, past, present, or future polishing steps can be changed. If the
current step's time is changed to a longer time than that which has transpired,
the remaining time showing will increase by the same amount as the
increase. If the current step's time is shorter than that which has transpired,
the step will end.
Many conditioning and machine parameters can be changed. However,
changes that could cause trouble, such as changing the number of spindles
used, will be ignored until the start of the next cycle.
Finally, all polish alarm parameters can be changed in the Alarms Menu.