Operations Model 6DS-SP Planarizer
5 - 32 Version 4.0 - February 1998
“LEFT SPINDLE FORCE LOW ALARM- # 1
“LEFT SPINDLE FORCE HIGH ALARM- # 2
“RIGHT SPINDLE FORCE LOW ALARM- # 5
“RIGHT SPINDLE FORCE HIGH ALARM- # 6
PART A
Problem
Indicator
Problem
Location
Component/ Cause Resolution/
Responsibility
ALARM
SOUNDS
DURING AUTO
POLISH
CYCLE
Control Panel.
The bottom of the
monitor screen
will display a
message showing
the cause.
(1) Machine
parameter out of
range of a
programmed alarm
parameter.
(2) Screen message
shows spindle force
alarm.
Note: The alarm is a
warning device--it does
not abort the cycle.
(1a) Read the bottom
of the screen for
message.
(1b) Press the CYCLE
HALT button.
(2a) Check alarm
parameters on Alarm
Parameters menu to
see if the alarm
parameters are within
range of the Auto
Polish Cycle
Parameter settings.
OPERATIONS