Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 33
“LEFT SPINDLE FORCE LOW ALARM- # 1
“LEFT SPINDLE FORCE HIGH ALARM- # 2
“RIGHT SPINDLE FORCE LOW ALARM- # 5
“RIGHT SPINDLE FORCE HIGH ALARM- # 6
PART B
Problem
Indicator
Problem
Location
Component/ Cause Resolution/
Responsibility
(3) Calibration of
E-P setting needed.
(2b) Check to be sure
facility air pressure =
100 PSI.
(2c) If facilities air
pressure = 100 PSI,
perform the Spindle
Force Calibration
procedure (per
Maintenance manual).
(3a) Perform the
Spindle E-P
Calibration, located in
the Software
Calibration chapter of
the 6DS-SP
Maintenance manual.