Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 53
“BRIDGE LUBE OIL LOW” - # 110
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Bridge
Lubricator needs to
be refilled.
(1a) Referring to the
Preventive
Maintenance chapter
of the 6DS-SP
Maintenance manual,
add the approved oil.
MAINTENANCE
“LOW COOLING WATER FLOW RATE” - # 111
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Neslab
temperature control
unit not operating.
(2) Water flow is
below Calibration
variable #175’s set
point.
(1a) Verify Neslab
power is on.
(1b) Verify Neslab
water reservoir is full.
(2a) Check to see that
variable #175 is within
an acceptable
operating range.
MAINTENANCE