EasyManua.ls Logo

Strasbaugh 6DS-SP - Page 323

Strasbaugh 6DS-SP
1562 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 65
“BRIDGE NOT ARRIVING AT LEFT CURTAIN - # 190
“BRIDGE NOT ARRIVING AT RIGHT CURTAIN - # 191
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Bridge servo not
arriving at the
commanded
position.
(2) Calibration
variable out of
range.
(1a) Servo tripped out--
Open and close polish
section operator doors
to reset.
(2a) Abort and rehome
axis.
OPERATIONS
“COND ARM NOT ARRIVING AT PARK- # 194
“COND ARM NOT ARRIVING AT INNER- # 195
“COND ARM NOT ARRIVING AT OUTER- # 196
Note: Error messages 194, 195, and 196 apply to the servo controlled
conditioning arm.
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Conditioning
arm servo not
arriving at the
commanded
position.
(2) Calibration
variable out of
range.
(1a) Servo tripped out--
Open and close polish
section operator doors
to reset.
(2a) Abort and rehome
axis.
OPERATIONS

Related product manuals