Strasbaugh Troubleshooting
Version 4.0 - February 1998 5 - 65
“BRIDGE NOT ARRIVING AT LEFT CURTAIN - # 190
“BRIDGE NOT ARRIVING AT RIGHT CURTAIN - # 191
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Bridge servo not
arriving at the
commanded
position.
(2) Calibration
variable out of
range.
(1a) Servo tripped out--
Open and close polish
section operator doors
to reset.
(2a) Abort and rehome
axis.
OPERATIONS
“COND ARM NOT ARRIVING AT PARK” - # 194
“COND ARM NOT ARRIVING AT INNER” - # 195
“COND ARM NOT ARRIVING AT OUTER” - # 196
Note: Error messages 194, 195, and 196 apply to the servo controlled
conditioning arm.
Problem
Indicator
Problem
Location
Component/ Cause
Resolution
ERROR
MESSAGE
Control
Computer
Screen
(1) Conditioning
arm servo not
arriving at the
commanded
position.
(2) Calibration
variable out of
range.
(1a) Servo tripped out--
Open and close polish
section operator doors
to reset.
(2a) Abort and rehome
axis.
OPERATIONS