Strasbaugh Installation
Version 4.0 - February 1998; Update 11/06/01 2 - 21 U
The slurry supply connection is a large 1/2" tube connection located near the
perimeter of the slurry cart cover with a stainless steel tube extending down
toward the bottom center of the slurry reservoir. This line should be connected
to the inlet port of the diaphragm pump. The slurry main return is also a large
3/8" tube located opposite the slurry supply connection on the slurry cart cover.
This tube should be connected to the slurry return connection on the slurry
dispensing manifold on the machine. Finally, the slurry filter return is a small
1/4" tube which connects to the center of the cover. This tube should be
connected to the fitting on the slurry valve assembly labeled filter return.
Both slurry systems should be completely connected before operating the
machine.