Maintenance Model 6DS-SP Planarizer
9 - 180 Version 4.0 - February 1998
RESTORATION OF ELECTRICAL POWER FOR
THE SECOND TABLE
A. BEFORE YOU BEGIN
Tools Required
flat blade screwdriver
Turn Machine Power Off
Follow the procedures detailed in the Operator Functions chapter of the 6DS-SP
Operations manual.
B. PROCEDURE TO RECONNECT 588, 589, AND 590
1. Open the door to the large electrical cabinet door.
2. Locate circuit breakers 19CB, 20CB, and 21CB, mounted on the left
wall of the cabinet.
3. Restore power to the second table by reattaching 588, 589, and 590:
a. Reattach 588 to 19CB.
b. Reattach 589 to 20CB.
c. Reattach 590 to 21CB.
4. Close the electrical cabinet door.