Maintenance Model 6DS-SP Planarizer
10 - 30 Version 4.0 - February 1998
D. TEST THE NEW ADJUSTMENT
1. Move the bridge to polish position (see the Before You Begin section,
above).
2. Repeat the Check Current Calibration section (above).
3. If needed, repeat the Adjustment Procedure section (above).
E. WHEN A SATISFACTORY ADJUSTMENT IS ACHIEVED
• Go on to Bridge Load Position Calibration, below.