Operations Model 6DS-SP Planarizer
2 - 18 Version 4.0 - February 1998
ADDITIONAL EMERGENCY OFF
BUTTONS
The 6DS-SP is equipped with a minimum of four EMERG OFF (emergency
off) pushbuttons. Additional buttons may be added, depending upon
customer specifications.
If the Mobile Remote Unit (SA 219187) is connected to the 6DSSP, the
Mobile Remote E.M.O. can be temporarily bypassed from the E.M.O. circuit
for up to thirty (30) seconds. During the temporary thirty (30) second bypass
of the Mobile Remote E.M.O. circuit, the Mobile Remote Unit E.M.O.
button WILL NOT BE OPERABLE! However, all other machine E.M.O.
buttons WILL remain operable.
Note: The bypass is made by depressing the 30 Second Timerpushbutton
with the yellow lamp next to the rotary switch on the Control Select
Panel at the rear of the machine. This is used only for the purpose of
connecting/disconnecting the Mobile Remote Units circular
connector plug to/from the 6DSSP without causing a machine E.M.O.
A yellow lamp on the pushbutton lights when the timer is counting
down from thirty (30) seconds to timeout, to alert operators that the
Mobile Remote E.M.O. is disabled during that thirty (30) second
period. If additional time is required, depressing the pushbutton at
any time immediately gives an additional thirty (30) seconds of
bypass time.
For further information on emergency off, cycle halting, and cycle
interruption, see the Operator Functions and Troubleshooting chapters of the
6DS-SP Operations manual.