Strasbaugh Pneumatic Adjustments
Version 4.0 - February 1998 11 - 3
PNEUMATIC
ADJUSTMENTS
OVERVIEW
IMPORTANT! After completing each adjustment below, RECORD all
dial gauge settings for use with the procedures in the Preventive
Maintenance chapter of this manual.
Assumption - The procedures below are discussed with the assumption that the
reader is thoroughly familiar with the 6DS-SP Planarizer. If not, see the chapters
in this manual on Physical Description, Installation, Mechanical Description,
Control System Description, Power Distribution, and Plumbing Description, as
well as the Operator Functions and Machine Setup chapters of the 6DS-SP
Operations manual, before beginning any procedure.
LOCKOUT SAFETY PROCEDURE
Refer to “Safety”, located in Chapter One of this manual, for a detailed
procedure for lockout of energy sources that could cause injury to personnel.
WARNING! All energy sources that could cause injury to personnel
must be locked out to protect against accidental or
inadvertent operation when such operation could cause
injury to personnel.