Strasbaugh Troubleshooting
Version 4.0 - February 1998 13 - 15
CYCLE WONT START--PART B
Problem
Indicator
Problem
Location
Component/ Cause Resolution/
Responsibility
NO RESPONSE
TO PRESSING
CYCLE START
BUTTON
No robot
movement; no
machine
movement
(8) Shuttle assembly
not tripping
forward reed
switch.
(9) Condi-tioning
brush not in park
position or not
tripping its park
reed switch.
(10) All 9 causes
and resolutions
have been
performed, and the
cycle will still not
start.
(8a) Check shuttle
position and
adjustment.
(9a) Check
conditioning brush
position and
adjustment.
MAINTENANCE
(10a) Call for
assistance.
STRASBAUGH
Note:
ANY of the cycle start errors (refer to error messages # 50-99 in Error Messages And
Alarms, below in this chapter) will inhibit a cycle start. Simply pressing the Cycle
Start button once will not always display the message. Instead, press and hold down
the Cycle Start button (up to 15 seconds) until an error message appears on the
screen.