operation.
2. Timed defrosting
a) If the spiral temperature sensor does not work
- The defrost mode will not turn on if the room temperature is higher than 25° C.
- If the room temperature is between 15 - 25° C and the appliance is in operation for at least 30 minutes,
defrosting will start. The defrost mode will last 10 minutes.
- If the room temperature is between 4 - 15° C and the appliance is in operation for at least 20 minutes, defrosting
will start. The defrost mode will last 12 minutes.
b) If the humidity sensor does not work
- If the spiral temperature is below C for at least 20 minutes and the appliance is in operation for at least 20
minutes, it will start to defrost.
- Defrosting ends when the spiral temperature is higher than 5° C for at least 90 seconds or after 25 minutes of
operation.
c) In case of non-functional spiral temperature and humidity sensors
- If the appliance is in operation for at least 40 minutes it will start to defrost.
- Defrosting ends after 10 minutes of operation.
Timer setting:
- Press the timer button to set the timer.
- Use the "+" and "-" buttons to set the required on / off time. (setting is accompanied by an audible signal).
After 10 seconds from setting the desired time, the time is stored in memory and the time setting indicator lights
up.
- Timer setting is possible in the range of 0-24 hours. The default value is 0.
- After the set time has elapsed, the appliance starts / stops operating.
Humidity setting:
- Press the timer button for more than 10 seconds.
- Use the "+" and "-" buttons to set the required humidity in the range of 10 - 95% (the setting is accompanied
by an audible signal).
- When the relative humidity in the room is lower than the set value, the appliance will operate. It switches off
when the set humidity value is reached.
- If the relative humidity rises again, the appliance switches on again.
Note: If the humidity is set to the minimum value (10%), the appliance switches to continuous dehumidification
mode by default.
- In the event of a fault in the humidity sensor, the appliance switches to continuous dehumidification mode.
- In the event of a fault in the spiral temperature sensor, the appliance switches to timed defrost mode
How to prevent system failure:
- With a continuous dehumidification mode of 10 minutes, increasing the outside temperature by C compared
to the spiral temperature for 10 consecutive seconds could result in system failure (eg coolant leakage or drain
hose clogging). If this happens, a warning will appear on the display and will be displayed until the fault is
rectified.