7.1 Battery
Only HURST lithium-ion rechargeable batteries may be used to operate the device. These
guarantee optimum performance and maximize the operating time of the device.
Charging state
display
Query button(I)
Technical Data nom. Voltage Capacity Energy Weight
Unit V DC Ah Wh kg
lb
Battery 25.2 3.9 98.3 1.2 2.6
NOTE:
To ensure maximum
operating time and maximum
uptime, you must make sure
that the battery is always fully
charged before connecting it
to a rescue device.
Release button
7. Accessories
NOTE:
Indicator lights are the
same as found on SCBA
systems (Self-Contained
Breathing Apparatus -
Symbols G, G, Y, R).
The charge status display is activated either by pressing a switch or activates automatically
when reaching a certain charge level (see table below).
Constant light
Constant light
Flashing yellow,
red continuous
light
Flashing red
till battery is
discharged
Automatic activationActivated by switch
Capacity
No
No
Yes
15 seconds activated and 45
seconds off. After 8 hours the
activation cycle will terminate
automatically.
Yes
After 8 hours the activation cycle
will terminate automatically.