33
12.2 Noise emission
Device type e100 / le100
Battery type used for device Lithium-ion
Idling (measured at a distance of 1 m,
according to EN)
[dB(A)] -
Full load (measured at a distance of 1 m,
according to EN)
[dB(A)] -
Idling (measured at a distance of 4 m,
according to NFPA)
[dB(A)] 67
Full load (measured at a distance of 4 m,
according to NFPA)
[dB(A)] 70
12.3 Operating and storage temperature ranges
Operating temperature, standard [°C] / [°F] -20 … +55 -4 … +131
Operating temperature extreme
range for 9 min., cyclical (device
operational)
[°C] /
[°F] -20 … +121 -4 … +250
Ambient temperature, standard
(device not operational)
[°C] /
[°F] -25 … +45 -13 … +113
Ambient temperature extreme range
for 7 min. (device not operational)
[°C] /
[°F] -30 … +149 -22 … +300
12.4 Oscillation / vibration
The total oscillation value / vibration value to which the upper limbs are exposed, is usually
below 2.5 m/s².
Higher values may be measured for short periods as a result of interaction with the materials
to be processed.
(The oscillations / vibrations were determined in accordance with DIN EN ISO 20643.)
12.5 Torque speci¿ cation and wrench size for pivot bolt
Device type e100 / le100
Pivot bolt M 24 x 1.5
Wrench size
[mm] 30
[in.] 1.18
Torque
[Nm] 100 +10
[lbfÂin] 885 + 89
Device including rechargeable battery