Fastener assembly weight 46 lb 21 kg
Minimum operators required for loading/unloading an occupied
cot
2
Minimum operators required for loading/unloading an
unoccupied cot
1
Recommended loading height 22 in. to 36 in. 56 cm to 91 cm
Electrical requirements - inductive charging (optional) 12.8 VDC-15.6 VDC, 15A fuse/breaker, 2 conductor 10
AWG cable
Standards KKK-A-1822F
With inductive charging: IEC 60601-1 Edition 3.0, IEC
60601-1 Edition 3.1, IEC 60601-1-2 Edition 3.0, IEC
60601-1-2 Edition 4.0, IEC 60601-1-12 Edition 1.0,
ANSI/AAMI ES60601-1: 2005/(R)2012, CSA-C22.2 No.
60601-1 (2014)
For standards that require specific options, see
Standards with required options
(page 6).
Stryker reserves the right to change specifications without notice. Patents pending.
The yellow and black color scheme is a proprietary trademark of Stryker Corporation.
EEnnvviirroonnmmeennttaall ccoonnddiittiioonnss
OOppeerraattiioonn SSttoorraaggee aanndd ttrraannssppoorrttaattiioonn
Temperature
130 °F
(54 °C)
-30 °F
(-34 °C)
158 °F
(70 °C)
-40 °F
(-40 °C)
Relative humidity
93%
0%
93%
0%
Atmospheric pressure
1060 hPa
620
1060 hPa
620
CCAAUUTTIIOONN
The use of accessories and cables, other than those specified, with the exception of cables that are sold by Stryker as
replacement parts for internal components, may result in increased emissions or decreased immunity of the
PPeerrffoorrmmaannccee--LLOOAADD system.
Do not use the PPeerrffoorrmmaannccee--LLOOAADD system and the PPoowweerr--PPRROO cot adjacent to or stacked with other equipment. If
adjacent or stacked use is necessary, observe the PPeerrffoorrmmaannccee--LLOOAADD system to confirm normal operation in the
configuration where it will be used.
Do not use portable RF communications equipment (including peripherals such as antenna cables and external
antennas) no closer than 30 cm (12 in.) to any part of the PPeerrffoorrmmaannccee--LLOOAADD system, including cables specified by
the manufacturer. Otherwise, degradation of the performance of this equipment could result.
The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11
class A). This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area (for which CISPR 11 class B is normally required) is likely to cause harmful interference
in which case the user will be required to correct the interference at their expense. In the event of interference, please
relocate or reorient the PPeerrffoorrmmaannccee--LLOOAADD system or interfering product.
SSttaannddaarrddss wwiitthh rreeqquuiirreedd ooppttiioonnss
To be compliant with the standards, you must use PPeerrffoorrmmaannccee--LLOOAADD with the following compatible cots. See the
Operations Manual for your cot model for more information.
EN 6 6392-009-001 Rev D.3