How to check calibration of humidity probe on Stulz Air Conditioner?
- AAndrew RothSep 23, 2025
To check the calibration of the humidity probe on your Stulz Air Conditioner, use a reference hygrometer.
How to check calibration of humidity probe on Stulz Air Conditioner?
To check the calibration of the humidity probe on your Stulz Air Conditioner, use a reference hygrometer.
How to fix a dirty filter alarm on Stulz Air Conditioner?
If you receive a 'dirty filter' alarm on your Stulz Air Conditioner, it means the air filter is clogged. Replace the filter to resolve this issue.
What to do if Stulz Air Conditioner shows a high humidity alarm?
If your Stulz Air Conditioner displays a 'high humidity' alarm (if a humidity probe is installed), it could be due to humidity infiltration from outside. Check for any air passages from the outdoors and seal them.
How to solve low temperature alarm on Stulz Air Conditioner?
If you are getting a 'low temperature' alarm on your Stulz Air Conditioner, you should improve the thermal insulation of the room or unit, or add external stand-alone heaters.
What to do for insufficient condenser air flow in Stulz Air Conditioner?
If there's insufficient condenser air flow in your Stulz Air Conditioner, ensure the condenser fan can move freely and clean the condenser and air openings.
How to check calibration of evaporator temperature probe on Stulz Air Conditioner?
To address a wrong calibration of the evaporator temperature probe in your Stulz Air Conditioner, check with a reference thermometer.
What to do if external temperature is higher than max limit for Stulz Air Conditioner?
If the external temperature is higher than the maximum limit for your Stulz Air Conditioner, change the unit model.
How to check calibration of condenser temperature probe on Stulz Air Conditioner?
To address a wrong calibration of the condenser temperature probe in your Stulz Air Conditioner, check it with a reference thermometer.
What to do when Stulz Air Conditioner cooling capacity is lower than heat load?
If the cooling capacity is lower than the heat load in your Stulz Air Conditioner, reduce the heat load or increase the number of units temperature.
What to do if pipes to the air flow switch are clogged in Stulz Air Conditioner?
If the pipes to the air flow switch are clogged or bent in your Stulz Air Conditioner, clean and reposition the plastic pipes.