PAGE 46
Error Code Table
CODE INDICATION
05 Refrig. Cabinet Thermistor read open or shorted for
10+ seconds, or repeatedly read erratic temp’s
06 Refrig. Evaporator Thermistor read open or shorted for
10+ seconds, or repeatedly read erratic temp’s
07 Freezer Cabinet Thermistor read open or shorted for
10+ seconds, or repeatedly read erratic temp’s
08 Freezer Evaporator Thermistor read open or shorted
for 10+ seconds, or repeatedly read erratic temp’s
20 Defrost Underheat with No Voltage Feedback Through
Gray/White Wire at Defrost Start
21 Defrost Overheat
22 No Voltage Feedback Through Gray/White Wire at
Defrost Start
23 Defrost Overheat with No Voltage Feedback through
Gray/White Wire at Defrost Start
24 Defrost Underheat
600 SERIES (Starting With Serial #1810000)
NOTE: Currently, Error Codes are registered because of thermistor
or defrost system errors only. The table above will be updated
through addendums when subsequent software and electrical
changes occur and more error codes are added.
To clear Error Codes, see next page.

Other manuals for Sub-Zero 600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sub-Zero 600 Series and is the answer not in the manual?

Sub-Zero 600 Series Specifications

General IconGeneral
TypeBuilt-In
Energy Star CertifiedYes
Ice MakerYes
LightingLED
Door AlarmYes
Temperature AlarmYes
ConfigurationSide-by-Side
Width36 inches
Height84 inches
Water DispenserYes
ShelvesAdjustable glass shelves

Related product manuals