PAGE 9
400 SERIES WINE STORAGE
» Temperature Log Recall Mode
1. Unit must be ON
2. Press and hold desired
compartment WARMER
key and the UNIT ON/OFF, then release both keys
NOTE: After performing the above key strokes, the fol-
lowing will appear on the display. Temperatures shown
are for reference only, actual temperatures may vary.
5533
SERVICE (Illuminated)
11
4 hour compartment temperature average (at left) with
index number. Number 1 is most recent 4 hour period.
NOTE: SERVICE is always illuminated at first index.
- Press WARMER key in multiple keystrokes to toggle
up through indexes, from 1 to 64.
6600 6644
4 hour compartment temperature average (at left) with
index number. Number 64 is oldest recorded 4 hour period.
- Press COLDER key in multiple keystrokes to toggle
down through indexes, from 64 to 1.
NOTE: See following page for possible event indicators
during Temperature Log Recall Mode. Temperature Log
Recall Mode will end 10-15 seconds after last key stroke.