4
|
Cove Customer Care 800.222.7820
Electrical Requirements
Installation must comply with all applicable electrical codes.
Any opening into the adjacent cabinet must meet the
following: the longest dimension of the opening shall not
be more than 1
1
/2" (38).
Locate the electrical supply in an adjacent cabinet, within
reach of the power cord. Refer to the illustrations below.
A separate circuit servicing only this appliance is required.
A ground fault circuit interrupter (GFCI) outlet or breaker
may be required, whichever complies with local codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 3'
(.9 m)
E
E
ELECTRICAL
LOCATION
IN ADJACENT
CABINET
FRONT VIEW
6"
(152)
2"
(51)
TOE KICK
SIDE VIEW
BACK OF
OPENING
Electrical location
Electrical routing
SPECIFICATIONS
23
5
/8" (600)
OPENING WIDTH
34
1
/
2
"
(876)
OPENING
HEIGHT
TOP VIEW
VIEW FRONT VIEW
3
1
/2" (89) finished returns will be visible and should be finished to match cabinetry.
3
/4" (19)
TYPICAL
FRAMED
CABINETRY
23
5
/8"
(600)
FILLER
3
1
/2" (89)
FINISHED
RETURN
FRAMELESS
CABINETRY
23
5
/8"
(600)
3
/4" (19)
TYPICAL
3
1
/2" (89)
FINISHED
RETURN
24" (610)
MIN OPENING
DEPTH
Opening Dimensions
DISHWASHER